"FLOW DIVIDER/COMBINER 3/8"" FLO"
Hydrokit Part Number : DDE0720BK0
Discontinued product replaced by :
50:50 FLOW DIVIDER 08-16 LPM ( DDE0816BDG01 )
Technical information
50/50 FLOW DIVIDER
- Bidirectional in-line installation
- Flow rate on inlet A: 8 to 20lpm
- Mountings: 3/8" BSP (A, B & C)
- Max. pressure: 350bar
- Specification: 5%
- Material: Zinc-plated bichromate
- Bidirectional in-line installation
- Flow rate on inlet A: 8 to 20lpm
- Mountings: 3/8" BSP (A, B & C)
- Max. pressure: 350bar
- Specification: 5%
- Material: Zinc-plated bichromate
Max pressure 315 bar Flow divided 50/50 (please contact us for other ratio)
Temperature -20° to +70°C
Double acting
Divids and cumulates the flow (bi-directionnal)
Simultaneous control and identical flow
2 cylinders without mechanical bond (eg : door)
2 circuits of hydraulic engines (eg : cut-off saw) JM
Input flow A ( l/mm ) | Apertures ( BSP ) | Reference | |
mini. | maxi. | A, B, et C | |
8 | 20 | 3/8 | DDE0720BK0 |
12 | 35 | 3/8 | DDE1235BK0 |
16 | 50 | 3/8 | DDE1650BK0 |
35 | 70 | 1/2 | DDE3570BK0 |
Technical data
Débit maxi | 20 | l/min | |
Max working pressure | 315 | bar | |
Implantation orifice P | G3/8 | ||
Implantation orifices A&B et/ou R | G3/8 |