COUPLING WITH POLYAMIDE RING
Hydrokit Part Number : ACP4
Discontinued product replaced by :
COUPLING WITH POLYAMIDE RING ( ACP4K )
Technical information
COUPLING WITH POLYAMIDE RING
Select the coupling according to the maximum load to exert. Find the corresponding coefficient F in the chart below and use it as shown in the formula:
Max speed (RPM) |
Power P by 100RPM |
Weight (kg) |
F (mm) |
A (mm) |
B (mm) |
C (mm) |
G (mm) |
H (mm) |
Drill hole J |
Reference | |||
kW |
HP |
Ø Max |
Ø Mini |
ØInitial hole | |||||||||
5000 |
0.75 |
1.00 |
0.85 |
40 |
66 |
44 |
38 |
4 |
84 |
28 |
10 |
8 |
ACP3 |
5000 |
1.32 |
1.75 |
1.65 |
42 |
90 |
60 |
52 |
4 |
88 |
42 |
14 |
12 |
ACP4 |
P à the coupling by 100 tr/mn |
= |
Theorical P x 100 x F |
|||
RPM |
|||||
Application |
Coefficient F | |
Electric motor |
Thermic motor | |
Constant load |
1.00 |
1.20 |
Moderate overload |
1.25 |
1.50 |
Considerable overload |
1.75 |
2.00 |