Technical information
- open centre with by-pass Max flow
rate: 40 L/min Max pressure 350 bar
counter-pressure on T: 210 bar max
with cabled control box 12 V - power
2 m - control 4 m > possibility of
controlling (or not) the by-pass
" Mounting on self-propelled vehicle and hydraulic power unit with reduced dimensions. Product advantages: Technical characteristics: Parallel section Divider By-pass Flow rate 40 l/min On P: 40 l/min On P: 40l/min Max. pressure P, A and B 350 bar 210 bar 350 bar Max pressure T 210 bar 210 bar 210 bar
Number of double-acting functions Dimensions of the distributor (L x w x h) - in mm 7 451 x 226 x 96
Single-acting, double-acting cylinder control, and hydraulic engine.
- Compact distributor (min. height of 96 mm).
- Practical: flow rate with priority for electric control or manual control.
- Modular: the adding of functions is possible (max. 8 sections).
- Very good value for money.
- Hydraulic:
Regulated: 0 to 25 l/min
Residual: 50 l/min
Technical data
Type of hydraulic circuit
Open center
Débit maxi
40
l/min
Max working pressure
210
bar
Nombre de section(s)
7
Type(s) Tiroir(s)
7DE + BP
Type of actuation
Commande Electrique 12vcc
Voltage
12 VCC
Volt
Implantation orifice P
G1/2
Implantation orifices A&B et/ou R
G3/8
Implantation orifice T
G1/2
Implantation orifice CS
sans
Boîtier Électrique
Avec